Descargar Imprimir esta página

Abicor Binzel xFUME POWER 350 Manual De Instrucciones Original página 67

Publicidad

Idiomas disponibles

Idiomas disponibles

xFUME POWER 350
Risk of injury due to fire
A fire may occur due to improper use or connection. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate is suitable for the mains voltage.
NOTICE
Material damage due to the use of too weak a generator
If the power is supplied by too weak a generator, this can result in not only material damage but also
irreparable damage to the device and the generator.
► Use only a generator that can guarantee 30% more power than the maximum power of the device.
For the mains voltage and the fuse protection, please refer to:
 4.4 Technical data on page EN-16
 15 Circuit diagram on page EN-45
► Plug in the mains plug.
7 Operation
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting container must be closed when operating the device.
► Do not open the dust collecting container until at least one minute has passed since the device was
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
Risk of injury due to fire
A fire may occur due to improper use or connection. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate corresponds to the connection voltage.
► Do not use the device to extract welding fumes that result from welding oil-wetted parts.
► Do not use the device to extract flammable substances and liquids.
► Do not use the device in areas subject to dust or gas explosion hazards.
NOTICE
Material damage due to exceeding the maximum duty cycle
If the device is operated for longer than the maximum duty cycle, it may be overloaded and irreparably
damaged.
► Only operate the device up to the maximum permissible duty cycle.
► Observe the maximum duty cycle for welding components.
7.1 Setting the shielding gas volume
Open the shielding gas cylinder.
1
Set the necessary shielding gas volume (6–18 l, depending on the welding current) on the
2
decompression valve's pressure regulator.
WARNING
Example: 14 kVA (device) + 30% = 18 kVA.
WARNING
switched off.
or a damp cloth.
WARNING
 4.4 Technical data on page EN-16
7 Operation
EN - 21

Publicidad