9 Maintenance and cleaning
9.4 Cleaning outer surfaces
Clean the outer surfaces with a suitable industrial vacuum cleaner (dust class H according
1
to DIN EN 60335-2-69 Appendix AA) or a damp cloth.
Dispose of cleaning residues/cloths in accordance with local regulations.
2
EN - 36
Switch off the power to the device.
1
Release the quick lock (G) and open the cover of the
2
extraction device (A).
Carefully remove the filter (B).
3
Place the filter (B) with the holes facing up.
4
Seal the holes with adhesive tape.
5
Dispose of the filter (B) in accordance with local
6
regulations.
Check the seals in the device for damage and replace if
7
required.
Insert the new filter (B), ensuring that the holes in the box
8
face backwards and line up with the extraction <IN> (D)
and <OUT> (C) holes in the device. The arrows on the
sides of the filter (I) must point upward.
Close the extraction unit's cover (A) and secure it with the
9
quick lock (G).
xFUME POWER 350