7 Operation
7.2 Setting up the wire feeder
Electric shock due to live parts
Fatal electric shocks can occur if components are live.
► Set the main switch to <0> before setting up the wire feeder.
► Disconnect the power supply.
Risk of crushing
Limbs can be crushed if device components are improperly installed or uninstalled.
► Keep your hands out of the danger zone.
► The wire feed unit's cover is heavy. Open and close the cover carefully.
► Check and wear your personal protective equipment.
Fig. 9
A Wire spool
B Wire spool holder
C Wire mandrel
D Wire mandrel hexagon socket screw
E 2× twist locks
J
I
H
7.2.1 Opening and closing the wire feeder's cover
EN - 22
WARNING
WARNING
Wire feeder
F
G
G
F Wire feed roller (behind knurled screw)
G 2× knurled screw
H Wire guide tube
I 2× pressure lever
J Wire spool adapter
F
E
Open the wire feeder's cover at the locking screws.
1
Fully open the cover.
2
Close the cover so the locking screws lock into place.
3