4.1- Power supply line wiring
Inside the transformer compartment there is a terminal with a 2 A pro-
tection fuse, connect the phase in the corresponding pole to the fuse.
4.2- Wiring for flashing light, courtesy light and gate movement warning light
1
M
Motor 1 Pedestrian
Terminal
Description
number
1-2
Output for powering the electric motor 1
(pedestrian)
3-4
Output for powering the electric motor 2
5-9
Courtesy light or second radio channel
6-7
Output for electrical lock control
8-9
Gate movement warning output
9-10
Accessories power supply output
11-12
Output for flashing light
4.3- Input connections:
The control unit is supplied with jumpered normally closed inputs (STOP, FOTO and STPA) remove the jumper from the input you are going to use.
13 14 15 16 17 18 19
EN
2
3
4
M
Motor 2
24 Vdc 65 mA max
Courtesy light or
second radio channel
Function
Output for controlling electric motor 1, 24 V dc rated power 50 W (1 opening, 2 closing)
Output for controlling electric motor 2, 24 V dc rated power 50 W (3 opening, 4 closing)
Output 24 V dc maximum load 65 mA, can be programmed as a timed output (100 sec-
onds) or second radio channel output, see parameter 34 (5= GND, 2can/ 9= + 24 V dc).
Output for electrical lock at 12 V ac maximum 15 VA
Gate movement warning output, flashes slowly when opening, on steady with gate open,
flashes quickly during closing and off with gate closed (8 = controlled GND, 9 = permanent
+ 24 V dc, maximum load 65 mA)
Output 24 V dc maximum 300 mA for supplying the photocells and accessories (9 = + 24
V dc, 10= GND)
Output at 24Vdc maximum load 15W for flashing light (11 = flashing light GND, 12 = + 24
V dc), if the automatic closing function is active, the flashing light is on steady during the
time of automatic closing.
Terminal number
Description
13-16
Control inputs common (permanent GND)
Sequential control input, for
14
controlling the complete travel of the gate
Sequential control input, for
15
controlling the pedestrian travel of the gate
17
Input for stopping the gate
Photocell input, active during
18
gate closing
Input for edges or internal photocell, active during
19
gate closing and opening
5
6
7
8
9 10 11 12
+
-
-
-
-
Electric lock
12 V 15 VA
Accessories power supply output
24 Vdc 300mA max
24 Vdc 65mA max
gate movement warn-
ing light
Neutral
neutro
Phase
fase
+
24 Vdc 15 W max
Input type
_
Normally open
Normally open
Normally closed
Normally closed
Normally closed
Terra
Fig. 4