9 - Installing batteries
Insert the battery charging circuit in the connector CN7 and connect the batteries. With battery operation only, the motor speed is 15% lower than the speed
with mains power. When operating on batteries only, the AC LED is off, the 2CAN output and AUX output for the flashing light are not active and the accessories
are powered only while the gate is moving.
N.B.: With battery operation and with no mains voltage, the leafs move one at a time both when opening and when closing without slowing down.
N.B: With battery operation you cannot save the remote controls, program gate travel (LRNE, LRN menu).
10 - Troubleshooting
Problem
The automatic gate system does not work
You cannot save the remote controls
As soon as the gate starts it stops and reverses
During slowdown, the gate stops
and reverses
Movement of one of the 2 motors is reversed
During calibration the motor M1 starts and stops
after 1 second
With the electrical lock the motor 1 is not able to
start opening or does not close completely
11 - Mechanical installation
For correct installation secure the box in a safe place where it is
protected from the weather. To secure the box in the wall you have
to remove the 4 plastic screws and open the cover.
Overall dimensions of control unit:
40 40
Cause
No mains supply
Blown fuses
Control and safety inputs not working
Safety devices open
Batteries of the remote control discharged
Remote control not compatible with the first one
saved
Reached memory saturation
Motor torque not sufficient
Slowdown speed too low
Wrong wiring
Encoder 1 wiring reversed with encoder 2
Electrical lock does not reset
Solution
Check the power line switch
Replace the fuses with others of the same value
Check the diagnosis LEDs (STOP, STPA and
PHOTO must be on)
Check the diagnosis LEDs (STOP, STPA and
PHOTO must be on)
Replace the batteries
The first saved remote control configures the con-
trol panel to save only rolling-code remote controls
or only dip-switch remote controls.
Delete at least one remote control or add an ex-
ternal receiver (maximum capacity 200 remote
controls)
Increase the motor force with parameter number
21 and 22
Increase the value of parameter 17-18-19 and 20
Check the motor wiring (1= opens M1/2= closes
M1/3= opens M2/ 4= closes M2)
Check the encoder wiring
Set parameter 32 ON (electric lock connection dis-
connection function)