N.B.: The first saved remote control configures the control panel to accept only remote controls with a rolling code or only remote controls with a fixed 12-bit
code
If you need to delete all the remote controls, enter the RAD menu, select ALL (between number 001 and 200), press and hold the OK button for 5 at least
seconds, and the display will show the 4 dots confirming the operation. N.B: With battery operation you cannot save the remote controls
It is advisable to fill in the final table indicating the number of the memory cell (it is displayed while saving the remote control) in the user name, this enables
deleting a remote control should it get lost.
7.3 LRN:
Learning travel with custom programming lets you define the points for starting deceleration when both opening and closing, save the point of
greatest opening of motor 1 and motor 2 and the offset times:
Requires mechanical stops when closing and both during programming and during normal operation.
x3
- Press the UP button 3 times, the display will show LRN
- Press the OK button to enter travel learning, the display will read APCH
- Press the APCH button
- M2 closes at slow speed until the mechanical stop and the display shows CLS2
- M1 closes at slow speed until the mechanical stop and the display shows CLS1
- After closing M1 the display shows LOC (operates the electric lock)
- M1 opens at cycle speed and the display shows OPN1
- Press APCH to set the starting point of deceleration for motor M1, the gate continues at slow speed until the mechanical stop, you can set the maximum
opening point before the mechanical stop by pressing the APCH button to stop and save the point.
- M2 opens at cycle speed and the display shows OPN2
- Press APCH to set the starting point of deceleration for motor M2, the display shows SLO, the gate continues at slow speed until the mechanical stop, you
can set the maximum opening point before the mechanical stop by pressing the APCH button to stop and save the point.
- M2 closes at cycle speed and the display shows CLS2
- Press APCH to set the starting point of deceleration for motor M2, the display shows SLO, the gate continues at slow speed until the mechanical stop.
- M1 closes at cycle speed and the display shows CLS1
- Press APCH to set the starting point of deceleration for motor M1, the display shows SLO, the gate continues at slow speed until the mechanical stop.
- M1 opens and the display reads 0000, as soon as you decide that the offset time of the gate leaf is sufficient, press button APCH, M2 will start opening and
the display will read 0000, the control panel will save the offset time for opening.
- After opening, M2 will start closing and the display will read 0000, as soon as you decide that the offset time of the gate leaf is sufficient, press button APCH,
M1 will start closing and the display will read 0000, the control panel will save the offset time for closing.
- After closing, the display will show END to indicate the end of the procedure.
N.B.: If the direction of gate leaf movement is incorrect, press the ESC button, the control panel will exit programming and block gate movement. Modify the
electrical wiring harness of the gearmotors and repeat the procedure.