7- Programmable Functions - Vimar ELVOX RS08 Manual De Instrucciones Para La Conexión Y El Uso

Tarjeta con pantalla 24 v para cancelas batientes
Ocultar thumbs Ver también para ELVOX RS08:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
6.3 Example of the procedure for changing the automatic closing time:
x4
1-
Press the UP button 4 times, the display will show PAR (parameters)
Press OK, the display will show P01
2-
3-
Press the UP button once, the display will show P02 (automatic closing time)
4-
Press the OK button, the display will show the automatic closing time
With the DOWN or UP button you can vary the automatic closing time
5-
6-
Press the OK button to confirm and save the modified value
7- Full description of the programming menu.
The programming menu is divided into 3 levels: first the main level, second the parameters level and third the values level.
Main menu:
Display Message
LRNE
Learning travel with quick programming (see section 6)
RAD
Remote control management
LRN
Learning travel with custom programming
PAR
Used to modify all the parameters of the control panel
DEF
Used to go back to the default values
CNT
Used to view the manoeuvres carried out
ERR
Used to view a list of the last 9 errors or malfunctions
PASS
Control panel protection level setting
After selecting the desired item from the main menu by pressing the UP or DOWN button, confirm by pressing OK.
7.1 LRNE: quick procedure for programming gate leaf travel
Requires mechanical stops both when opening and closing and during programming and during normal operation.
1
6
11
1-
Press the UP button once, the display will show LRNE
2-
Confirm with the OK button, the display will show APCH
3-
Press the APCH button
4-
The display reads CLS2, motor M2 closes until the mechanical stop
5-
After closing M2, M1 starts to close and the display shows CLS1
EN
2
3
7
8
12
Description
4
9
5
10
31 31

Publicidad

Tabla de contenido
loading

Tabla de contenido