Vimar ELVOX RS08 Manual De Instrucciones Para La Conexión Y El Uso página 37

Tarjeta con pantalla 24 v para cancelas batientes
Ocultar thumbs Ver también para ELVOX RS08:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
Parameter number Description
P29
Offset for opening
P30
Offset for closing
P31
Motors present
Hammering and electric hook recon-
P32
nection
P33
Electric lock activation time
P34
Selects the operation of the second
button on the remote control
P35
Channel 2 output activation time
P36
Pedestrian opening distance
P37
Flashing light active also when run-
ning only on battery
P38
Operation with battery
P39
Manned
P40
Force on mechanical stops
P41
Separate buttons
P42
Operation with solar panel
P43
Type of gearmotors
SINGLE LEAF: If you are using the control panel to govern a single leaf, connect the motor to output M1 and proceed with the calibration of the travel, the
control panel is configured automatically for single-leaf operation, after calibration parameters 10-12-14-16-18 -20-22-24-26-29-30 will no longer be active.
OPERATION WITH NO ENCODER: If no encoder is connected you need to remove the encoder interface card before powering up the control panel, param-
eters 13-14-15-16-25-26 will no longer be active
N.B.: After calibrating the travel, if parameters 13-14-15-16-17-18-19-20 and 43 are changed after confirming with the OK key the display reads APCH, you
must give the command by pressing the APCH button, the gate will perform a complete opening and closing cycle (with this operation, the control unit saves
the new current thresholds with the modified speeds)
7.5 DEF:
used to set the control panel on the default parameters except for parameters 9-10-11-12-29-30-31-36-40, press and release the OK button, the
display shows 4 dots to confirm the operation.
To set all the parameters to default: power up the control panel by holding down the ESC key for at least 10 seconds.
7.6 CNT:
used to view the number of openings followed by the gearmotor, the first counter A displays the number of absolute operations, the second counter
P displays the operations performed after a reset controlled by the installer. This is shown in the following example:
x6
EN
Settable values
From 0 to 60 seconds
From 0 to 60 seconds
1 motor or 2 motors
ON/OFF
From 0 to 10 seconds
2CH= activates the 2CH output
PED= controls pedestrian opening
From 1 to 60 seconds
From 0 to 100% of total travel
ON/OFF
0: functionality does not change
1: after an apch command the gate opens and remains
open
2: the gate opens and remains open
0: function disabled
1: function active if the safety devices are open (PHOTO
and STPA) controlled by APCH for opening and by Aped
for closing
2: function active with apch and ped inputs, maintains
automatic operation if controlled remotely, controlled by
APCH for opening and by Aped for closing
Detection of the mechanical stop:
from 0 (fast) to 5 (maximum delay)
0= AP/CH controls complete opening and closing of the
gate,
PED controls partial opening and closing of the gate
1= input AP/CH controls opening only and input PED con-
trols closing only
2= input AP/CH and the button of the remote control saved
as CH1 controls opening only and the
PED input and the button of the remote control saved as
CH2
controls closing only
ON/OFF
1=EI20 underground at 12v to 2m
4=EA25 linear gearmotor 12V to 2.5m
5=EA50 linear gearmotor 12V to 3.5m
x5
Default value
Modified value
3 seconds
6 seconds
2
OFF
3
PED
1
100%
OFF
0
0
1
0
OFF
4
35

Publicidad

Tabla de contenido
loading

Tabla de contenido