7.4- PAR:
Used to modify all the parameters of the control unit, press the UP button until PAR appears on the display, confirm with the OK button to display
the list of parameters, the display will show P01 (parameter number 1), the UP or DOWN button lets you scroll through the list of parameters (see parameter
table)
x4
Parameter table
Parameter
number
Description
P01
Enables automatic closing
P02
Sets the automatic closing time
P03
AP/CH input operation
P04
Pre-flash
P05
Closing after photocell disengagement
P06
Type of safety device connected to the
STPA input
P07
AUX output operating mode
P08
Enables photocell control
P09
Slowdown distance when closing M1
P10
Slowdown distance when closing M2
P11
Slowdown distance when opening M1
P12
Slowdown distance when opening M2
P13
Opening speed M1
P14
Opening speed M2
P15
Closing speed M1
P16
Closing speed M2
P17
Opening deceleration speed M1
P18
Opening deceleration speed M2
P19
Closing deceleration speed M1
P20
Closing deceleration speed M2
P21
Motor M1 force
P22
Motor M2 force
P23
Acceleration on starting M1
P24
Acceleration on starting M2
P25
Deceleration on slowing down M1
P26
Deceleration on slowing down M2
P27
-
P28
-
34
Press the button until you
see the parameter to be
modified
Settable values
ON/OFF
0-600 seconds
1= when opening, AP/CH input not active
(condo)
2=AP/CH as sequential (open, stop, close, stop..)
3=AP/CH as sequential (open, open, close..)
ON/OFF
ON/OFF
1= photocell as protection on opening
(if engaged it stops the gate, until it is disengaged, and then it contin-
ues opening)
2= microswitch sensitive edge
3= resistive sensitive edge (balanced with resistance (8.2Kohm)
ON = slow flash during opening, steady with gate open, fast flash
during closing
OFF = on steady while moving and with gate open, and off when the
gate is closed
OFF= Control disabled, 1= Control on PHOTO input
2= Control on STPA input, 3= Control on STPA and PHOTO inputs
From 0 to 100% of travel
From 0 to 100% of travel
From 0 to 100% of travel
From 0 to 100% of travel
From 50 to 100%
From 50 to 100%
From 50 to 100%
From 50 to 100%
(15 - 75 with encoder), (35 - 70 without encoder)
(15 - 75 with encoder), (35 - 70 without encoder)
(15 - 75 with encoder), (35 - 70 without encoder)
(15 - 75 with encoder), (35 - 70 without encoder)
From 1 minimum to 10 maximum
From 1 minimum to 10 maximum
1-5 ( 1=maximum acceleration 5= minimum acceleration)
1-5 ( 1=maximum acceleration 5= minimum acceleration)
1-8 ( 8= maximum deceleration 1= minimum deceleration)
1-8 ( 8= maximum deceleration 1= minimum deceleration)
Default
Modified
value
value
ON
60 sec-
onds
1
ON
OFF
1
ON
OFF
30%
30%
70%
70%
100%
100%
100%
100%
50%
50%
50%
50%
5
5
3
3
6
6
EN