30. DC Control Cables:
CAUTION
Before making electrical connections,
verify the red disconnect switch on the side panel is in the
OFF position.
A) Fasten the "A" labeled terminal end of the FA9190-8
cable to the positive terminal of the motor, Fig. 37 and
Fig. 37a. Fasten the other end of FA9190-8 cable to the
empty motor contact terminal, Fig. 37b.
B) Fasten the "B" labeled terminal end of the FA9190-
12 red cable to the "Battery" side of the disconnect
switch. (Note: FA9190-12 black cable wired to ground
from charger), Fig. 37b.
C) Fasten the "C" labeled terminal end of the FA9190-6
red cable to the small right terminal contactor, Fig. 37b.
(Note: FA9190-6 black cable wired to ground.)
D) Attach battery post connectors to the positive and
negative posts on both the top and bottom batteries,
Fig. 37.
E) Fasten the "D" labeled terminal end of the FA9190-9
cable to the positive post of the top battery, Fig. 37. The
FA9190-9 cable is shipped connected to disconnect.
F) Fasten the "E" labeled terminal end of the FA9190-7
cable to the negative post of the top battery, Fig 37.
G) Fasten the "F" labeled terminal end of the FA9190-7
cable to the positive post of the bottom battery, Fig 37.
H) Fasten the FA9190-5 black cable to the negative post
of the bottom battery, terminal "G", Fig. 37. The op-
posite end is shipped connected to ground.
I)
Fasten the "H" labeled terminal end of the FA9190-
10 cable to the negative post of the bottom battery,
terminal "H", Fig. 37. Fasten the other end of the
FA9190-10 cable to the negative motor terminal, Fig.
CAUTION
37a.
CAUTION
When removing batteries always
disconnect black FA9190-10 ground cable first.
J) Re-attach top and bottom cover, Fig. 38.
27