32. Charger Cable & Overhead Switch Cable:
A) Plug the male end of the 10 foot charger cable into the
receptacle on the back of the DC control cabinet.
B) Route the charger and overhead switch cable to the top
of the power unit column extensions by wire tying them
to the overhead hose.
33. Overhead Switch: Connect the overhead switch
cable to the overhead switch using the included
wire nuts.
34. Receptacle:
A) Mount the receptacle box to the extension directly
above the DC control cabinet with the included #12-
24NC x ¾" long pan head machine screws and nuts,
Figure 40. Be sure to mount #12 star washers to one
mounting screw as shown in Figure 40. This is very
important for grounding.
B) Remove the hole punch covering the hole in the recep-
tacle box than lines up with the hole in the extension.
Mount the included 1/2" cord grip thru the hole in the
extension and receptacle box.
C) Mount the included ground wire hook terminal using
the included green self-tapping ground screw through
the grounding hole in the receptacle box.
D) Fasten the receptacle to the receptacle box cover with
the included fastener and the cover to the box with the
included fasteners. The ears on the top and bottom of
the receptacle may need to be removed to allow it to fit
inside the cover properly. Fasten the tinned end inside
the ground terminal of the receptacle.
35. Electrical: Have a certified electrician run appropriate
power supply to the 120 volt receptacles mounted at the top
of the lift.
LIFT ELECTRICAL INPUT: 110-120 Volt, 60 Hz, 3.15 Amps
Note: A separate circuit is not required for each Shock-
Wave DC powerunit.
CAUTION: Never operate the motor on line voltage. Motor
damage may occur.
36. Laser Spotter: Mount the laser using the instructions
included with the laser spotting kit.
37. Plug-in Laser and Charger:
A) Plug the laser into the bottom receptacle and wire tie it
to the receptacle box, Figure 40.
B) Plug the charger cable into the top receptacle. Check
to make sure the charger lights are on. If charger lights
are not on, flip switch on back of charger.
38. Close DC Control Cabinet: Re-attach the front plastic
covers to the DC control cabinet using the same button
head cap screws, Figure 38.
31