DANGER
I
To avoid injury, never put lubricants on
the blade while it is spinning.
,_ WARNING
I
To avoid fire or toxic reaction, never
use gasoline, naphtha, acetone,
lacquer thinner or other similar highly
volatile solvents to clean the miter
saw.
To avoid injury from unexpected
starting or electrical shock, unplug
the power cord before working on the
saw.
For your safety, this saw is double-
insulated. To avoid electrical shock,
fire or injury use only parts identical
to those identified in the schematic
diagram.
NOTE: Used but serviceable brushes can
be replaced, but only as long as they are
returned to the same position, and inserted
the same way round, as they were removed
from the machine.
Run new brushes without load for
approximately 5 minutes. This will help
the break-in process.
\
CHECKING AND REPLACING CARBON
BRUSHES (Fig. AA)
Replace both carbon brushes if either has
less than 1Ain. length of carbon remaining, or
if the spring or wire is damaged or burned.
To remove the brushes:
Unscrew the plastic caps found at the
back of the motor. Be careful as the
caps are spring-loaded.
Withdraw the brushes with their springs.
If replacement is necessary insert new
brushes and replace the caps.
(Fig. AA) Diagrams showtop and bottom
brush caps.
34