until the wheel stops before raising the guard.
Dynamic balancing (Dynamic)
This balancing mode is the most commonly used
one. If a different balancing programme is run-
ning, the programme must be set by selecting
the correct icons.
Now proceed as follows:
-
Press the Dimensions button
enable automatic dimension measurement.
The button remains pressed and the inner light
turns red
-
Spin the wheel by lowering the guard.
To ensure accurate results, do not apply undue
stress to the machine during the spin and do not
interfere with telecamera and laser sensor scanning.
-
Wait for the wheel to stop automatically (the
wheel guard will raise up automatically) and
the display the imbalances.
At the end of the run, if the function of the
automatic position search function is activated,
the wheel may turn upwardly raised.
At the end of the scanning of the front laser
triangulator, the device prepares, when rotating
the wheel, at the plane acquired, that is, at the
rim of the rim where the spring weight will be
applied.
Using buttons
era can be adapted to ambient lighting conditions.
If the automatic capture of the border is NOT
corrected, it can be changed within the LIVE en-
vironment (to enter the LIVE environment, select
the button
). Select one of the two video
imbalances Select the horizontal arrow then use
one of the three methods below to store the new
EYELIGHT Plus DiagnosticLine - Operator's manual
to
.
the telecam-
position by reminding you that the laser point
indicates the spring-weight application bar:
1. Turn the wheel clockwise or anticlockwise to
change the position of the laser point until
the start of rim lights up, then press the Enter
button
or the button
rise it and then the Exit button
2. Modify the spring weight application board
directly on the monitor using your finger
as a slider inside the image,
Enter button
to memorise it and then the Exit button
.
3. Using the arrows
limetre by millimetre to find the border of the
rim. When you think you have found the cor-
rect position, confirm by pressing the Enter
button
or the button
rise it and then the Exit button
If the spring weight plane is selected by pressing
and releasing the button
to change its position by following the instruc-
tions below:
1. Press and hold down the button then turn
the wheel clockwise or counterclockwise to
change the position of the laser point until it
illuminates the edge for applying the spring
weight. Release the button
the new position and exit the program using
the exit button.
It is also possible to change the rim of the circle
in a work environment as well, following the
instructions below:
to memo-
.
or the button
move mil-
to memo-
.
, it is possible
to store
61