user according to the specific shape of the rim.
However, bear in mind that it is always prefer-
able to select balancing planes as far apart as
possible in order to reduce the quantity of the
weight to be applied; if the distance between
the two planes is less than 37 mm (1.5"), the A
64 message is displayed.
-
Select the first side to be balanced.
-
Rotate the wheel until the central element of
the corresponding position indicator lights
up.
-
Apply the balancing weight in the position
indicated on the screen.
-
Repeat the operations listed for the second
side of the wheel.
Application of spring balancing
weights
-
Select the plane where the balancing weight
is to be applied.
-
Turn the wheel until the central part of the
corresponding position indicator lights up
or press the centre of the round indicator to
start the automatic position search.
-
Place the clip weight in the 12 o'clock position.
Application of adhesive
balancing weights
-
Select the plane where the balancing weight
is to be applied.
-
Turn the wheel until the central part of the
corresponding position indicator lights up
or press the centre of the round indicator to
start the automatic position search.
-
The internal laser pointer automatically comes
out indicating the exact position for applying
the adhesive weight.
-
in this phase, if the balancing position is
NOT correct, it can be changed by pressing
and holding down the button
turning the wheel clockwise or anticlockwise
to change the position of the laser point
until the centre of the surface selected for
the application of the adhesive weight is
illuminated. Release the button to store the
new position.
WARNING
The previously described procedure de-
termines the possible unbalance variation
displayed by the machine on both surfaces,
therefore it is recommended to apply the
64
-
The rim surface must be perfectly clean to make
the weight stick efficiently to the rim. If neces-
sary, clean the surface using suitable cleansing
products.
Note: the adhesive weights outside the rim folder
in the ALU3 and ALU4 balancing programmes
should be applied manually in the 12 o' clock
position.
programme (available only with
ALU1 and ALU2 programmes)
The Hidden Weight programme should be used
on alloy rims in conjunction only with the ALU1
or ALU2 programmes when the external weight
then
needs to be hidden behind two spokes for
aesthetic reasons. This programme subdivides
the outer balancing weight (Pe) into two equal
weights (P1 and P2) placed in concealed positions
behind two spokes of the alloy rim.
EYELIGHT Plus DiagnosticLine - Operator's manual
weights after the balancing position is chan-
ged.
Apply the adhesive weight as indicated in the
figure.
i ^ pbo
"Hidden Weight" automatic