Now proceed as follows:
Press the Dimensions button
-
enable automatic dimension measurement.
The button remains pressed and the inner
light turns red
-
Spin the wheel by lowering the guard.
-
If you want to change any planes of an ad-
hesive weight or a spring weight, select the
corresponding imbalance in the LIVE environ-
ment (to enter the LIVE environment, select
the button
new position remembering that the laser point
indicates the centre of the adhesive weight
using one of the 3 methods described below:
1. Turn the wheel clockwise or anticlockwise
to change the position of the laser point
until the centre of the plane selected for
application of the adhesive weight lights
up or the edge for applying spring weight;
then press the Enter button
button
to memorise the posi-
tion and then the Exit button
2. Modify the center of the chosen plane for
the application of the adhesive weight or
the edge in the case of spring weight directly
on the monitor using your finger as a slider
inside the image, press the Enter
button
or the button
rise it and then the Exit button
3. Using the arrows
limetre by millimetre to find the centre of the
plane selected for application of the adhesive
weight. When the correct position has been
found, confirm by pressing the Enter button
or the button
EYELIGHT Plus DiagnosticLine - Operator's manual
to
.
) and then memorise the
or the
to memo-
move mil-
and then the Exit
button
If the plan of an adhesive weight or a spring
weight is selected by pressing and releasing
the button
its position by following the instructions
below:
1. press and hold down the button
turn the wheel clockwise or anticlockwise to
change the position of the laser point until
the centre of the surface selected for the ap-
plication of the adhesive weight or the edge
for applying spring weight is illuminated.
Release the button to store the new position.
Repeat the procedure to change the second
balancing surface if necessary, otherwise exit
the programme using the exit key
.
Also, it is possible to modify a plan of adhesive
weight or the edge of a spring weight even in
a working environment following the instruc-
tions given below:
-
press and hold the button
.
the wheel clockwise or counterclockwise to
change the position of the laser point until it
does not illuminate the center of the chosen
plane for applying the adhesive weight or
the edge for applying the weight to spring.
Release the button
new position and exit the program. If the but-
ton
is pressed with the machine in
Center Position (GREEN COLOR MESSAGE)
then you can ONLY change the plane related
.
to this imbalance. While the button
is pressed off the Centered Position, you can
repeat the procedure to change the second
balancing plane if necessary.
Note: the balancing planes where the adhesive
weights are to be applied may be selected by the
.
, it is possible to change
then
then turn
to store the