Error Messages - Corghi EYELIGHT Plus Diagnostic Line Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

-
Perform a third spin. This last calibration phase
consists of three consecutive spins executed
automatically.
If the calibration has been successful, a permis-
sion acoustic signal goes off at the end of the
spin; otherwise, the E 2 message is temporarily
displayed.
Notes:
- Once the procedure is finished, remove the
calibration weight.
-
Press the key to interrupt the calibration
procedure at any time.
-
This calibration is valid for any kind of wheel.
6.4. Service
This programme displays some data that are
used to test machine operation and to detect
the malfunctioning of some devices. Since these
data are not useful for the operator, it is recom-
mended that only technical support technicians
consult them.

ERROR MESSAGES

The machine can recognise a certain number
of malfunction conditions and signals them by
displaying the relevant messages.
– A – Notice messages
A 3
wheel not suitable for performing the sensitivity
calibration, use a wheel of average dimensions
(typically 5.5"X14") or larger but with a weight
that does not exceed 40 kg.
A 7
The machine is temporarily not enabled to select
the programme requested. Perform a spin, then
76
repeat the request.
A 25
Programme not available.
A 31
Optimisation procedure (OPT) already launched
by another user.
A 51
Spin with automatic wheel clamping system
open or incorrect wheel clamping. Repeat the
locking operation.
A 52
Hub mounting/demounting procedure started
automatic wheel clamping system. The procedure
stops automatically after 30 seconds. Press the
21
Stop button to interrupt the procedure.
A 60
Incorrect rim spoke storage procedure.
Carefully follow the instructions on the screen or
those in the Hidden weight section.
A 61
Incorrect automatic wheel width measurement.
Repeat the spin with automatic dimension acqui-
sition. If the problem persists, enter the correct
rim width value manually.
A 62
Incorrect automatic wheel width measurement.
Repeat the spin with automatic dimension acqui-
sition. If the problem persists, enter the correct
rim width value manually.
A 63
Incorrectly measured wheel dimensions. Repeat
the spin. If the error persists, set the dimensions
manually.
A 64
Incorrect plane acquisition point setting. Repeat
manual positioning of planes.
A 65
Wheel dimensions error. Repeat the spin. If the
error persists, set the dimensions manually.
A 66
Obstacle detected or wheel diameter less than 10"
during internal measuring sensor movement. Re-
peat the spin or insert the dimensions manually.
A 99
Incorrect calibration phase. Repeat the spin, fol-
lowing the procedure described in this manual.
A Stp
Wheel stop during the spin phase.
A Cr
Spin performed with the guard raised. Lower the
guard to perform the spin.
EYELIGHT Plus DiagnosticLine - Operator's manual