PRO Line - Mara - PL62S · PL62 · PL62T
Point the steam wand at the cup rack and release some steam at least once.
Clean the wand (4) carefully with a sponge or a clean cloth. The chapter on "Cleaning and
maintenance" provides all the necessary instructions.
I
Hot water distribution
I.1 Place a jug under the hot water nozzle (12) and open the hot water knob (11) by
44
turning it anti-clockwise until you have the quantity of hot water required.
I.2 Close the hot water knob (11).
for experts
Changing the settings
The PID is set by the factory to 121°C. Instructions for adjusting the setting are
given below.
J
Adjusting the boiler temperature
J.1 Press the "down" button.
J.2 When the display shows "PRG" press the "up" button.
J.3 When the display shows the boiler temperature, set the temperature us-
ing the "up" and "down" buttons till you reach the required temperature: min
110°C – max 126°C.
J.4 Use the "up" and "down" buttons to adjust the temperature as desidered.
J.5 About 3 seconds after the last button has been pressed, the setting will be
saved and the display will indicate the temperature.
Note.
about 3 seconds. When the display shows "C-F", release both buttons and afterwards press the
button "up" to convert the temperature from Celsius degrees to Fahrenheit degrees. About 3 sec-
onds after the last button has been pressed, the setting will be saved.
Converting the temperature: press "down" and "up" buttons at the same time for
(only for PL62T)