Descargar Imprimir esta página

Cambro PRO CART ULTRA Manual Del Propietário página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
VII. Troubleshooting Guide (continued)
In normal operation, the probe temperature will be displayed. The display
blinks when waiting for a parameter to be saved or when there is an error
saving a parameter to memory. The following messages can also appear:
ERP1 Probe Error (check wiring or replace probe)
Eri
Internal Parameter Error (factory default programming)
ALH
High Temperature Alarm
ALL
Low Temperature Alarm
ooo
Open Probe Error
---
Short Circuited Probe Error
Please contact service if problem persists.
VIII. Instructions for Security Package (S) Models
1. Remove the #10 Pin-in-Torx screw from the Black Rubber retainer with a T-25 PIT driver bit.
2. Slide the column out of the compartment and verify the rail positions at the desired positions for your application.
3. Install two stainless steel rods (see image) through the small holes in each of the lower tabs of the rails assembled to the column.
Additional rods can be purchased and installed in the center positions for added security.
4. Verify that each rail tab has a rod threaded through its hole.
5. Slide the completed assembly back into the compartment and re-install the screw back into the original hole.
7
STEP 4
6
5
4
3
STEP 3
STEP 2
STEP 5
2
1
F
E
D
C
B
9
A

Publicidad

loading