SC Series Controllers
Troubleshooting
Message
Possible Cause
Network needs to
know that a valid
unprocessed part has
entered the station
Accumulated bolt
count is equal to Job/
Task bolt count
A input is applied that
is assigned as STOP
Job/ Task Verify
inputs not matching
selected Job/ Task
The controller is in
the process of
booting
The Cycle Lock-out
timer is active
Reject Count
Exceeded
Logic criteria not met
for tool operation
Tool is not armed
A Reset Reject is
active
124 / 1032
Probable Solution
Major Considera-
tion That Led to
Solution
Have a valid part
Tool Disabled:
enter the station
Network Protocol
message on display
when the operator
pressed the tool's
start trigger
Select a new Job/
Tool Disabled: Error
Task.
Proofing message
on display when the
Reset the Job.
operator pressed the
tool's start trigger
Remove the active
Tool Disabled: Stop
input.
Issued message on
display when the
Reassign input.
operator pressed the
tool's start trigger
Select a different
Tool Disabled: Stop
Job/Task.
Issued message on
display when the
Select a different
operator pressed the
socket for
tool's start trigger
verification.
Wait until the
Tool Disabled:
controller has
System Initializing
finished the boot up
message on display
process
when the operator
pressed the tool's
start trigger
Wait for the timer to
Tool Disabled: Cycle
reset.
Lock-out message
on display when the
Change the Cycle
operator pressed the
Lock-out timer value.
tool's start trigger
Reset the Job
Tool Disabled:
Reject Count
Exceeded message
on display when the
operator pressed the
tool's start trigger
Retrain operator on
Tool Disabled:
proper process to
Internal PLC
insure the internal
message on display
PLC logic is met
when the operator
pressed the tool's
start trigger
Press the MFB to
Tool Disabled: Not
arm the tool
Armed message
appears on display
whenever the
operator presses the
tool's start trigger
Press the MFB to
Tool Disabled: Not
acknowledge and
Armed message
reset the NOK
appears on display
fastening cycle
To Clear/Reset from
Message Condition
Have a valid part
enter the station.
Disconnect the
Ethernet cable from
the controller.
Select a new Job/
Task.
Reset the Job.
Remove the active
input.
Reassign input
Select a different
Job/Task. Select a
different socket for
verification.
Wait until the
controller has
finished the boot up
process
Wait for the timer to
reset.
Change the Cycle
Lock-out timer value.
Reset the Job
Retrain operator on
proper process to
insure the internal
PLC logic is met.
Delete the PLC
program.
Press the MFB to
arm the tool.
Change the tool's
parameter to not
require arming.
Press the MFB to
acknowledge and
reset the NOK
fastening cycle.