SC Series Controllers
Configuration
8.1.1.2.1
Task menu
Manage:
Add
Adds a Task to the controller. If a tool is attached, the Wizard begins for easy setup of
parameters. If a tool is not attached the Tasks tab appears for manual parameter setup.
Select the add button and select the task number from the dropdown list to insert new task
in that position then click OK.
Delete
Deletes the selected Task from the controller. Tasks cannot be recovered once deleted.
Copy
Copies the selected Task and its associated Steps to the Clipboard.
Paste
Overwrites the selected Task with the values residing in the Clipboard.
To copy/ move a Task: First create a new Task where it is needed, then copy the Task to
be moved, then paste into the new Task created.
Cancel
Cancel the manage menu.
Save:
Save the changes.
Cancel:
Cancel the changes.
8.1.1.2.2
Step
Under Setup card header -> Select Jobs card -> Select Job card header -> Select Task card header -> Step
Name:
Provides an identifier for the step (15 characters maximum). Use the up/down arrows for letters or use the
numeric keypad.
Strategy (Standard):
Identifies values used to control the tool during a Step and to control the Step's direction. Strategies include:
TC / AM
AC / TM
42 / 1032
Torque Control with Angle Monitor. The controller shuts off the tool when the target
torque value is achieved. The controller also monitors angle which can indicate
changes in joint rate. Audit Step torque and angle results must fall within their
specified limits for the fastening cycle to be acceptable (OK).
Angle Control with Torque Monitor. The controller shuts off the tool when the target
angle value is achieved after a selected snug torque value. The controller also
monitors torque. Audit Step torque and angle readings must fall within their specified
limits for the fastening cycle to be acceptable.