SC Series Controllers
Configuration
Outputs
Description
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
START TRIGGER Asserts when the tool's trigger is pressed. Resets when the tool trigger is released.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
STEP (BIT)
Asserts at the end of the fastening cycle to indicate the last step ran. This is one bit, in a
series of bits, to create a binary number.
Size: 1 bit, except on fieldbus where it can be any size to fit the need.
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Bit: Type the number this bit will be in the binary number scheme for steps.
Mode: All STEP BITs must be the same mode, no mixing of modes allowed.
Binary – Creates a decimal number equivalent to the weighted value of this binary bit(s).
Binary + 1 – Creates a number equivalent to the weighted value of this binary bit(s) and
add the value of one (1) to that number.
Spindle: Type the spindle number from which the signal comes.
STOPPED
Asserts when the STOP input is received, or anytime the tool is stopped. Resets when the
STOP input or the Stop Tool Operation is reset. The icon is on when this output is on.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
TASK COMPLETE Asserts when a task is complete (all bolts assigned to task are OK). Resets when a task is
selected.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Task: Type the task number that, when completed, asserts this output.
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
TASK SELECTED Asserts when a task is selected by any means. Resets when the active task is complete.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Task: Type the task number that, when selected, asserts this output.
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
TASK SELECTED
Asserts when required to indicate the active task. This is one bit in a series of bits to create
BIT
a binary number. As tasks change so will the binary number created from these bits.
Size: 1 bit, except on fieldbus where it can be any size to fit the need.
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Bit: Type the number this bit will be in the binary number scheme for selected tasks.
Mode: All TASK SELECTED BITs must be the same mode, no mixing of modes allowed.