Outputs
Description
Binary – Creates a decimal number equivalent to the weighted value of this binary bit(s).
Binary + 1 – Creates a number equivalent to the weighted value of this binary bit(s) and
add the value of one (1) to that number.
Spindle: Type the spindle number from which the signal comes.
TOOL RUNNING
Asserts anytime the tool is energized. Resets when the tool is commanded to stop.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
*TORQUE
This output is the peak achieved torque value during the fastening cycle from the Audit
step. It asserts when the fastening cycle is complete (before the IN CYCLE bit resets). The
value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Step: Audit, Audit-1, Audit-2
Spindle: Type the spindle number from which the signal comes.
TORQUE HIGH
Asserts at the end of a fastening cycle when the achieved torque value is above the High
Torque limit for the Audit step. Resets when the tool is commanded to start again. Can
also be reset with the RESET RESULTS STATUS input.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Step: Audit, Audit-1, Audut-2
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
TORQUE LOW
Asserts at the end of a fastening cycle when the achieved torque value is below the Low
Torque limits Audit step. Resets when the tool is commanded to start again. Can also be
reset with the RESET RESULTS STATUS input.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Step: Audit, Audit-1, Audut-2
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
TORQUE OK
Asserts at the end of a fastening cycle when the achieved torque value is within limits for
the Audit step. Resets when the tool is commanded to start again. Can also be reset with
the RESET RESULTS STATUS input.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Step: Audit, Audit-1, Audut-2
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.