Descargar Imprimir esta página

Stanley SC Serie Manual De Instrucciones página 39

Publicidad

This identifies whether the tool disables after each Task has completed. This requires a Reset Job, Task
Select or Task Select Bit input to select an incomplete Task which enables the tool for an incomplete Task
only. If Auto Sequence Task is used, the tool reenables when the active Task switches to an incomplete
Task.
● On Task Complete
If enabled, disables the tool when the active Task is complete.
Enable Job Timer
If enabled, it invokes the Job Timer. The Job Timer starts when the first bolt of the batch count exceeds
Threshold Torque (In Cycle) and stops when the programmed number of seconds has elapsed. If the timer
times out before the batch count is complete the Job is set to complete, the tool is disabled, and the Job
Complete output is energized.
1. Job Timer:
Input the field with job time in seconds.
8.1.1.1
Jobs menu
Manage
Add
Adds a Job to the controller. If a tool is attached, the Wizard begins for easy setup of
parameters. If a tool is not attached, the Jobs tab appears for manual parameter setup.
Select the job number and click OK.
Delete
Deletes the selected Job from the controller. Jobs cannot be recovered once deleted.
Copy
Prompts user to select a job to copy.
Paste
Prompts user to select a job number for a previously copied job.
Cancel
Cancel the manage menu.
Import
● Alpha tool box:
Prompts user to select a job parameter file for import from local storage.
● Physical display:
On SC controllers physical display user can import job parameter file from the USB drive.
Export
● Alpha tool box:
Saves a job backup file to a selected storage medium.
● Physical display:
On SC controllers physical display user can export the job parameter file to USB drive.
Save:
Saves the changes.
Cancel:
Cancels the changes.
SC Series Controllers
Configuration
39 / 1032

Publicidad

loading

Este manual también es adecuado para:

Scn