Outputs
Description
*RUNDOWN BOLT Accumulated Bolt Count of last fastening cycle Data Type, Spindle
*RUNDOWN DAY
Day of last fastening cycle
*RUNDOWN HOUR Hour of last fastening cycle
*RUNDOWN JOB
Job of last fastening cycle
*RUNDOWN
Minute of last fastening cycle
MINUTE
*RUNDOWN
Month of last fastening cycle
MONTH
*RUNDOWN PART
Last fastening cycle PART ID
ID
*RUNDOWN
Second of last fastening cycle
SECOND
*RUNDOWN
Overall status of last fastening cycle
STATUS
*RUNDOWN TASK Task of last fastening cycle
*RUNDOWN UNITS Torque Units of last fastening cycle
*RUNDOWN YEAR Year of last fastening cycle
SNUG ACHIEVED
Is set when Snug torque exceeded
START TRIGGER
Shows the state of the tool trigger
STEP BIT
Indicates last step of fastening cycle in a
series of bits
STOPPED
A STOP input is asserted
TASK COMPLETE
Task complete (all bolts in task are OK)
TASK SELECTED
Indicates a specific task is selected
TASK SELECTED
A bit to indicate the selected task in a series of
(BIT)
bits
TOOL RUNNING
The tool is running
*TORQUE
Torque result value
TORQUE HIGH
Fastening cycle Torque exceeded High limit
TORQUE LOW
Fastening cycle Torque under Low limit
TORQUE OK
Fastening cycle Torque was within limits
*TORQUE STATUS Torque status of last fastening cycle
YELLOW LIGHT
Mimics the Yellow Light on the controller
* Output not available on 24 VDC
8.1.3.2
Input descriptions
Most SC controllers contain a 24V DC Input and Output Connector. Each of the single bit input functions has a
Configuration setting of Contact Type. The Contact Type can be Normally Open (N.O.) or Normally Closed
(N.C.). If an input's contact type is normally open, the input is asserted when 24V DC is applied to the 24V DC
connector input pin, or when the fieldbus bit transitions from low to high. If an input's contact type is normally
closed, the input is asserted when 24V DC is removed from the 24V DC connector input pin, or when the
fieldbus bit transitions from high to low.
The Input functions assert on the transition only.
SC Series Controllers
Configuration Options
Data Type, Spindle
Data Type, Spindle
Data Type, Spindle
Data Type, Spindle
Data Type, Spindle
Data Type, Spindle
Data Type, Spindle
Data Type, OK, NOK, Spindle
Data Type, Spindle
Data Type, Spindle
Data Type, Spindle
Contact Type, Type, Time, Spindle
Contact Type, Type, Time, Spindle
Contact Type, Bit, Mode, Spindle
Contact Type, Type, Time, Spindle
Contact Type, Type, Time, Task, Spindle
Contact Type, Type, Time, Task, Spindle
Contact Type, Bit, Mode, Spindle
Contact Type, Type, Time, Spindle
Data Type, Step, Spindle
Contact Type, Type, Time, Step, Spindle
Contact Type, Type, Time, Step, Spindle
Contact Type, Type, Time, Step, Spindle
Data Type, Step, OK, Low, High, Spindle
Contact Type, Type, Time, Spindle
Configuration