Combination Possibilities; Explanation Of Warning Symbols - Ottobock 8E33 Serie Instrucciones De Uso

Ocultar thumbs Ver también para 8E33 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
Various control programmes make optimal adaptation to the individual needs and abilities pos­
sible.
Only with 8E33=9* and 8E34=9*
The terminal device is based on the Ottobock DMC system (DMC=Dynamic Mode Control): This
system, which has been developed by Ottobock, uses two independent measurement and control
systems in order to optimally control the gripping speed and gripping force in accordance with
the muscle signal.

2.3 Combination possibilities

This product can be combined with the following Ottobock components:
Power supply (rechargeable battery)
757B35=0 MyoEnergy Integral
757B35=1/757B35=3 MyoEnergy Integral
757B15 X-ChangePack
757B20/757B21 EnergyPack
Battery chargers
The following battery chargers can be used
depending on the rechargeable battery:
757L14 battery charger
757L20 battery charger
757L35 battery charger
3 Application
3.1 Indications for use
The System Electric Greifers are intended exclusively for exoprosthetic upper limb fittings.
3.2 Use/Field of Application
The System Electric Greifers can be used for unilateral or bilateral amputations, and in case of
dysmelia.
3.3 Environmental conditions
The prosthesis system was developed for everyday activities and must not be used for unusual
activities. These unusual activities include, for example, sports with excessive strain and/or
shocks to the wrist joint (pushups, downhill racing, mountain biking, ...) or extreme sports (free
climbing, paragliding, etc.). Furthermore, the prosthesis system should not be used for the oper­
ation of motor vehicles, heavy equipment (e.g. construction machines), industrial machines or
motor-driven equipment.
The product is intended exclusively for use on one patient. Use of the product by another person
is not approved by the manufacturer.
Permissible ambient conditions are described in the technical data (see Page 23).
3.4 Qualification
Fitting a patient with the product may only be carried out by orthopaedic technicians who have
been authorised by Ottobock after completion of a corresponding training course.
4 Safety

4.1 Explanation of warning symbols

Warning regarding possible serious risks of accident or injury.
WARNING
Warning regarding possible risks of accident or injury.
CAUTION
Lamination rings
10S1=50 lamination ring
9S110=50 lamination ring
Rotation
10S17 electric wrist rotator
13E205 MyoRotronic
Elbow
ErgoArm Hybrid plus: 12K44
ErgoArm Electronic plus: 12K50
DynamicArm: 12K100N/12K110N
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

8e34 serie

Tabla de contenido