Installation
Instructions
REQUIREMENTS FOR ALCOVE OR
CLOSET
INSTALLATION
. Your dryer
is approved
for
installation
in an
alcove or closet, as stated on a label on the dryer
back.
. The dryer MUST be vented to the outdoors.
See
the EXHAUSTING THE DRYERsection.
. Minimum
clearance
between
dryer cabinet
and
adjacent walls or other surfaces is:
0" either side
3" frontand rear
. Minimum
vertical
space from floor to overhead
shelves, cabinets, ceilings, etc., is 52".
. Closet
doors
must
be Iouvered
or otherwise
ventilated
and have at least 60 square
inches
of open
area equally
distributed.
If the closet
contains
both a washer and a dryer, doors must
contain a minimum
of 120 square inches of open
area equally distributed.
. The closet should
be vented to the outdoors
to
prevent gas pocketing in case of gas in the supply
line.
. No other fuel-burning
appliance
shall be installed
in the same closet with the dryer (gas models
only).
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, MINIMUM
CLEARANCE
FROM THE WALL IS 5.5 INCHES.
BATHROOM OR BEDROOM INSTALLATION
. The dryer MUST be vented to the outdoors. See
EXHAUSTING THE DRYER.
. The installation
must conform
with local codes or,
in the absence of local codes, with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric
dryers) or NATIONAL FUEL GAS CODE, ANSI Z223
(for gas dryers).
MOBILE OR MANUFACTURED
HOME
INSTALLATION
. The
installation
must
conform
to
the
MANUFACTURED
HOME
CONSTRUCTION
&
SAFETYSTANDARD, TITLE 24, PART 32-80 or, when
such standard
is not applicable,
with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME, NO.
50lB.
. The dryer MUST be vented to the outdoors
with
the termination
securely
fastened
to the mobile
home structure.
(See EXHAUSTING THE DRYER.)
. The vent
MUST NOT be terminated
beneath
a
mobile or manufactured
home.
. The vent duct material
MUST BE METAL.
. FOR GAS MODELS ONLY: KIT 14-D346-33
MUST be
used to attach the dryer securely to the structure.
. FOR GAS MODELS ONLY: The vent MUST NOT be
connected
to any other duct, vent or chimney.
. Do not use sheet metal screws or other refastening
devices
which
extend
into the
interior
of the
exhaust vent.
. Provide an opening with a free area of at least 25
sq. in. for introduction
of outside air into the dryer
room.
GARAGE INSTALLATION
(IF ALLOWED
BY LOCAL CODES}
. Dryers installed in garages
must be elevated 18
inches (46cm) above the floor.
16