GAS REQUIREMENTS
A WARNING
. Installation
must
conform
to
local codes
and
ordinances, or in their absence, with the National
Fuel Gas Code, ANSI Z223.Z/NFPA 54, or the Natural
Gas and Propane Installation Code, CSA B149.1.
. This gas dryer
is equipped
with
a Valve
and
Burner Assembly for use only with natural
gas.
Using conversion
kit 14-A048, your local service
organization
can convert this dryer for use with
propane (LP)gas. ALL CONVERSIONSMUST BE MADE
BY PROPERLY TRAINED AND QUALIFIED PERSONNEL
AND IN ACCORDANCE WITH LOCAL CODES AND
ORDINANCE REQUIREMENTS.
, The dryer must be disconnected from the gas supply
piping system during any pressure testing of that
system at a test pressure in excess of 0.5 PSI (3.4
KPa).
, The dryer must be isolated from the gas supply
piping system by closing the equipment
shut-off
valve during any pressure testing of the gas supply
piping of test pressure equal to or less than 0.5 PSI
(3.4KPa).
DRYER GAS SUPPLY CONNECTION
2" 15.1 cm)
I
2Yd' (6.7 cm)
3/8"
NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
You must
use with
this
dryer
a flexible
metal
connector
(listed connector
ANSI Z21.24 / CSA 6.10).
The length of the connect
shall not exceed 3 ft.
GAS SUPPLY
. A 1/8"
National
Pipe Taper
thread
plugged
tapping,
accessible
for test gauge connection,
must be installed
immediately
upstream
of the
gas supply
connection
to the
dryer. Contact
your local gas utility should you have questions
on the installation
of the plugged tapping.
. Supply line is to be 1/2" rigid pipe and equipped
with an accessible shutoff within 6 feet of, and
in the same room with, the dryer.
. Use pipe thread
compound
appropriate
for
natural or LP gas or use Teflon ® tape.
, Connect flexible
metal connector
to dryer and
gas supply.
IN THE COMMONWEALTH
OF
MASSACHUSETTS
. This product must be installed by a licensed
plumber or gas fitter.
. When using ball-type gas shut-off valves, they
shall be the T-handle type.
. A flexible gas connector,
when used, must not
exceed 3 feet.
ADJUSTING
FOR ELEVATION
Gas clothes
dryers input ratings are based on
sea level operation
and need not be adjusted
for operation
at or below 2000 ft. elevation.
For
operation
at elevations
above
2000 ft., input
ratings should be reduced at a rate of a percent
for each 1000 ft. above sea level.
Installation
must conform
to local codes and
ordinances
or, in their absence, with the National
Fuel Gas Code, ANSI Z223.1/NFPA
54, or the
Natural Gas and Propane Installation
Code, CSA
B149.1
19