SPECIFICATIONS
Maximum SurgeWatts .................
5,625 watts
Continuous Wattage Capacity ...........
4,500 watts
Power Factor ..............................
1.0
Rated Maximum Continuous AC Load Current:
At 120Volts .......................
37.5Amps
At 240 Volts .......................
18.7Amps
Phase.................................
I-phase
Rated Frequency .......................
60 Hertz
FuelTank Capacity ...................
7 U.S.gallons
ShippingWeight .........................
164 Ibs.
GENERAL
MAINTENANCE
RECOMMENDATIONS
The Owner/Operator
is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis;that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate
a
damaged or defective generator.
Engine
Maintenance
See engine owner's manual for instructions.
Maintenance
Minder
The maintenance minder displaysand records how many
hours your generator has run (up to 9,999.9). It also alerts
you when to change your oil and to service your air filter.
The message"CHG OIL" will flash after the first 20 hours
of unit operation.This is to remind you to replace the
'break-in' oil with regular duty oiLThe same messagewill
again flash after intervalsof 100 hours.The maintenance
reminder does not sense that the oil change has occurred -
it merely flashes the messagefor a two hour period to
permit you to observe the reminder.
Similarly,the message"SVC AIR FILTER" will flash after
intervalsof 50 hours to remind you to service or change
the air filter element
_ii
CAUTION!When
working on the generator,
always disconnect spark plug wire from spark plug
and keep it away from spark plug.
_ii
AUTION!
Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES.RETURN
USED OIL TO COLLECTION CENTERS.
Generator
Maintenance
Generator
maintenance
consists
of keeping
the unit clean
and dry. Operate
and store
the unit
in a dean
dry
environment
where
it w{{{ not be exposed
to excessive
dust, dirt, moisture
or any corrosive
vapors.
Cooling
air
slots
in the generator
must
not become
clogged
with snow,
leaves or any other
foreign
material.
NOTE:
DO
NOT
use a garden
hose to dean
generator.
Water
can enter
engine
fuel system
and cause problems.
In
addition,
if water
enters
generator
through
cooling
air slots,
some
of the water
wilt be retained
in voids
and cracks
of
the rotor
and stator
winding
insulation.Water
and dirt
buildup
on the generator
internal
windings
will
eventually
decrease
the insulation
resistance
of these
windings.
To Clean
the Generator
_ii
AUTION!
NEVER insert any object or tool
through the air cooling
slots, even
if the engine is
not running.
• Use a damp cloth to wipe exterior surfaces clean.
• A soft bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspectcooting air slots and opening on
generator.These openings must be kept clean and
unobstructed.
/