61000-3-2
Method: This test consists on the measurement of harmonics components of the input current which may be produced by
equipment having an input current up to and including 16 A per phase, and intended to be
connected to public low-voltage distribution systems. The equipment is tested under specified conditions of
Laboratory Parameters
Ambient Temperature
Relative Humidity
Equipment mode
Supplementary information: This 10W equipement is compliant for harmonic current emissions without measurement. (p<75W)
Electromagnetic emissions
1.8 Test Conditions And Results - Limits for Harmonic Current Emissions
TEST: Limits for Harmonic current emissions (IEC 61000-3-2: - use latest edition)
operation.
Classification of Equipment
Required prior to the test
15 to 35 °C
30 to 60 %
Power interface mode
EUT configurations mode
Operation mode
92
Verdict
P
During the test
-
-
230V 5OHz
2
2
Class A