3.9.2 Menu rtc - TIME, DAY, DATE SETTING
To set the clock it is necessary to access the Rtc menu , by
pressing the "SET"
key the value from "t01" to "t06" will
appear.
Value
Description
t01
Hours
t02
Minutes
Day of the week
t03
(1= Monday... - 7=
Sunday)
t04
Day of the month
t05
Month
t06
Year
Level: U=user menu - I=installer menu
NOTE: for a CASCADE system, the clock setting must
be performed only on the MASTER. Once modified, it will
be necessary to power off and power on the MASTER so
that the latter communicates the set time to the SLAVEs.
By pressing the "SET"
modified, its value can be modified using the "+" and "-" keys.
Then press the "SET"
the modification) and the "ON/OFF"
3.9.3 Sch MENU - TIME BANDS PROGRAMMING
Before activating the weekly programming it is neces-
sary to set the time, day and date of the appliance.
NOTE: in case of application of several units in cascade, the
programming of the time bands must be performed only on the
master unit.
To set the weekly programming, access the menu Sch.
By pressing the "SET"
ar and by pressing the "SET"
lue "0" will appear (it means that time band program-
200 HT - 260 HT
Action
While editing a parameter
Allows you to return to the previous
menu without saving the changes
made
If pressed for more than 3 seconds, it
allows saving the entered parameter
value and returning to the previous
menu.
Saving will be confirmed by a beep.
Allows you to increase or decrease
the value of the selected parameter.
Minimum
Value
value
maximum
00
23
00
59
0
6
1
31
1
12
20
50
key again on the parameter to be
key to confirm (a beep will confirm
key to exit the menu.
key, "d_0" will appe-
key again, the va-
cod. 3540000420 - Rev. 03 - 09/2023
ming is disabled, default value). To activate time band
programming, use the "+" and "-" keys to bring the value to "1".
Subsequently you can choose the days on which to set the
programming according to the values in the table:
Value
d_1
Monday
d_2
Tuesday
d_3
Wednesday
d_4
Thursday
d_5
Friday
d_6
Saturday
d_7
Sunday
Level: U=user menu - I=installer menu
Weekly programming allows you to define 6 distinct operating
time bands for each day of the week.
Level
Value
U / I
d1A
Time slot 1
U / I
d1b
Time slot 2
d1c
Time slot 3
U / I
d1d
Time slot 4
d1E
Time slot 5
U / I
d1F
Time slot 6
U / I
Level: U=user menu - I=installer menu
U / I
For each band it is possible to define the operating mode (stan-
dard or silenced), the set point, the start and end time and, in
the case of a cascade of water heaters.
For example: by accessing the "d1A" menu, by pressing the
"SET"
key and scrolling with the "+" and "-" keys, the values
from "1A1" to "1A9" will appear.
Value
Description
Enabling/Disa-
1A1
bling time band 1
1A2
Band 1 start time
1A3
Time slot 1 starts
1A4
Band 1 end time
Band 1 end
1A5
minutes
Band 1 operating
1A6
mode
1A7
Band 1 setpoint
Enabling/Disa-
1A8
bling Silent mode
in band 1
Cascade level in
1A9
band 1
Level: U=user menu - I=installer menu
By pressing the "SET"
modified, its value can be modified using the "+" and "-" keys.
Description
Description
Unit of
default min
max
mea-
sure
0
0
1
-
(0=disabled, 1=enabled)
00
00
23
ora
00:23
00
00
45
min
00, 15, 30, 45
00
00
23
ora
00:23
00
00
45
min
00, 15, 30, 45
2:5= (2=ECO, 3=AUTO,
2
2
5
-
4=BOOSTER, 5=ELEC-
TRIC HEATING)
38:62 / 38:75 (depending
50
38
75
°C
on the mode selected)
0
0
1
-
(0=disabled, 1=enabled)
0:2= (0=min, 1=medium,
0
0
2
-
2=max)
key again on the parameter to be
EN
Level
U / I
U / I
U / I
U / I
U / I
U / I
U / I
Level
U / I
U / I
U / I
U / I
U / I
U / I
Note
Level
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
143