Ferroli EGEA TECH 200 HT Manual De Uso, Instalación Y Mantenimiento página 145

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
EGEA TECH
Value
Description
Et3 *
Weekly thermal energy
Et4
Monthly thermal energy
Et5
Annual thermal energy
Et6
Total thermal energy
Level: U=user menu - I=installer menu
Menu E_r
Value
Description
Er1 *
Instant renewable energy
Er2
Daily renewable energy
Er3 *
Weekly renewable energy
Er4
Monthly renewable energy
Er5
Annual renewable energy
Er6
Total renewable energy
Level: U=user menu - I=installer menu
Press the "ON/OFF"
key to exit the menu.
Reading example
To display the instantaneous consumption of a value in the
E_A sub-menu, it is necessary to select the EA1 value.
The display of the value is carried out in several consecutive
screens.
To scroll through the screens use the "+" and "-" keys.
In this example the reading is done by joining all the values
found in the 3 screens:
First screen:
Second screen:
Third screen:
Pulse la tecla "ON/OFF"
fig. 2 - first reading screen
fig. 3 - second reading screen
fig. 4 - third reading screen
200 HT - 260 HT
Unit of measure
Level
kWh / 10 *
U / I
kWh
U / I
kWh
U / I
kWh x 10**
U / I
Unit of
measure
Wh / 10 *
U / I
Wh
U / I
kWh / 10 *
U / I
kWh
U / I
kWh
U / I
kWh x 10**
U / I
00 (see fig. 2)
28 (see fig. 3)
59 (see fig. 4)
para salir del menú.
cod. 3540000420 - Rev. 03 - 09/2023
NOTA:
* : for the correct reading of this parameter, the va-
lue resulting from the 3 screens must be divided by 10.
Ex. 02859 / 10 = 285,9
** : for the correct reading of this parameter, the value re-
sulting from the 3 screens must be multiplied by 10.
Ex: 02859 x 10 = 28590
3.9.6 rSt menu - RESET
Level
Para-
meter
n01 Weekly programming reset
n02 Energy monitoring counter reset
Level: U=user menu - I=installer menu
To perform the reset:
set the parameter = 1
power off the unit
power on the unit.
3.9.7 Inf MENU - MACHINE STATUS INFORMATION
To view the general information, access the Inf menu by pres-
sing the "SET"
the values "I01" to "I13" will appear.
Para-
Description
meter
Currently active operating
I01
mode
I02
real water set point*
I03
External air temperature
I04
Lower water temperature
I05
Higher water temperature
I06
Evaporator inlet temperature °C
Evaporator outlet tempe-
I07
rature
Compressor delivery tem-
I08
perature
I09
Coil temperature
PT1000 solar probe tem-
I10
perature
I11
-
Calculated evaporation
I12
temperature
Calculated condensing
I13
temperature
Electronic expansion valve
I14
opening
I15
Fan rpm number
I16
WiFi module firmware
I17
Motherboard firmware
I18
Display firmware
I19
Parameter version
Level: U=user menu - I=installer menu
* : the displayed value also takes into account any offsets linked to the
activation of the auxiliary functions (photovoltaic, smartgrid, solar thermal,
anti-legionella).
Press the "ON/OFF"
Description
Note Level min
-
0
-
0
key and scrolling with the "+" and "-" keys,
Note
0:6 (0=OFF, 1=STANDBY, 2=ECO, 3=AUTO,
4=BOOSTER, 5=ELECTRIC, 6=FAN)
°C
°C
°C
°C
°C
°C
°C
°C
Reserved
°C
°C
Step
rpm / 10
-
-
-
-
key to exit the menu.
EN
max
Livello
U / I
0
1
U / I
0
1
Level
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
U / I
145