Imesa IM6 Instrucciones De Uso página 28

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

E030101C
"WASH 5 STEP 4: HEATING INSERT AFTER".
Press "ENTER " to insert the fifth step.
Display appears "WASH 5: STEP 4: HEATING
INSERT AFTER LOAD". Use "+" or "-" to select
from the step menu the step wanted "WASH";
press "ENTER".
Display appears "WASH 5: STEP 5: WASH
MODIFY".
Press "ENTER". On the display appears "WASH
5: STEP 5: WASHING TYPE MOTOR". Use "+" or
"-" to select the step parameters. To modify one of
the parameters value, press "ENTER" and use "+"
or "-" to increase or reduce, the value. In this step
modify the parameters TYPE MOTOR (same as
1), DRUM SPEED (same as 40 rpm), the TIME
(same as 5 minutes). When all the parameters are
programmed, press "MENU". On the display
appears "STEP MODIFY: CONFIRM?".
Press "ENTER" to confirm, or "STOP" to cancel.
Display appears "WASH 5: STEP 4:WASHING
MODIFY".
Now cycle programming is completed with the 5
steps.Press "MENU" more times to scroll upwards
to other menus.
21. STEPS
Steps are of nine kinds and are herebelow listed
with their meanings:
-DRAIN : drains water up to a programmable level
(in cms) or for a pprgrammable time
- LOAD: loads water up to a programmable level
or for a programmable time
- COOLING: provides for water drain up to desired
level and lets in fresh water up to a max.
programmable level. Procedure is eventually
repeated until required temperature is reached.
- HEATING: provides for water heating until
required water temperature is reached
- WASHING DURATION: provides for drum
revolving on programmable time and temp. basis
- DETERGENTS: provides for detergents loading
on quantity and time of loading basis
- SPREADING DURATION: provides to spread
linen around drum (at 100 rpm with closed drain
valve) on programmable time basis
- SPIN DURATION: provides for spinning (up to
1000
rpm
with
closed
programmable time basis.
- GENERIC: is one step without specifications that
permits the use of all suitable relay.
A total of 430 steps may be stored. Setting up a
new step mean means completing it with its
parameters. Steps set in a logical sequence,
compose a cycle. (see § 18).
22. STEP PARAMETERS
Parameters used for building a new step are:
-
MOTOR TYPE: is the designation of a
washing rotation in terms of revolving
speed,
clockwise
drain
valve)
on
and
anti-clockwise
sense and interval
-
DRUM SPEED: is the designation of drum
rotating speed in rpm
-
COLD W. INLET: when activated fresh
water will flow through cold water inlet
valve into drum
-
HOT W. INLET: when activated warm
water will flow through hot water inlet into
drum
-
SOFTNER: when activated, water will
Flow through the 3
box
-
DETERGENT 1: when activated cold
Water will flow through 1st compartment
of soap box; in case of washer equipped
with detergent pumps, pump No. 1 will
work
-
DETERGENT 2: when activated warm
Water will flow through 2
of soap box; in case of washer equipped
with more pumps (at least 2), pump 2 will
work
-
DETERGENT 3: in case of washer
equipped with at least 3 pumps, pump No.
3 will work
-
DETERGENT 4: in case of washer
equipped with at least 4 pumps, pump no.
4 will work
-
FREE 1: is one free relay, activable inside
of one generic step
-
FREE 2: is one free relay, activable inside
of one generic step
-
DETERGENT PUMP: 1,2,3,4,5,6,7,8: in
case of washer equipped with more than
4 pumps, pumps 5,6,7,8,9,10,11,12 will
work
-
LOAD BALANCE: when activated, 5 cms
of cold water will be let in, warm water will
then be let in; both inlet valves will be
open until correct levels and temperatures
will be reached
-
LEVEL: end step for water level in the
drum (in cms)
EXAMPLE 1: loading step with level
parameter of 15 cms: washer will keep on
loading water until such level of water in
the drum is reached
EXAMPLE 2: drain step with level
parameter of 5 cms, drain valve will be
open until such level is reached.
-
MIN. LEVEL: is required only when a step
of cooling is activated and designs water
level to be reached when warm water is
drained (expressed in centimeter);
-
MAX LEVEL: is required only when a
cooling is activated and designs a water
level to be reached when cold water is
loaded (expressed in centimeter);
-
LAPSE: is required only with a cooling
step
and
decreasing speed in °C.
28
30/11/2003
rd
compartment of soap
nd
compartment
designs
the
temperature

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido