HANGING THE FAN (continued)
Standard Ceiling Installation
Hanger Ball
WARNING: All set screws must be checked, and retightened where necessary,
before installation.
Set Screw
Step 1. Pass the 120-volt supply wires through the center hole in the ceiling mounting bracket as
Cross Pin
shown in (Fig. 5).
Step 2. Secure the ceiling mounting bracket to the ceiling outlet box with the screws
Downrod
and washers provided with your outlet box.
Hitch Pin
Step 3. Remove the retaining clip and the hitch pin from the hanger ball/downrod assembly.
Remove the hanger ball from the hanger ball/downrod assembly by loosening the set screw
Fig. 6
(do not remove) on the hanger ball, unscrewing and removing the cross pin, and unscrewing the
hanger ball from the downrod. (Fig. 6)
Retaining
Clip
Step 4. Loosen the two set screws (do not remove) in the coupling on top of the motor
assembly. (Fig. 7)
Supply
Wires
Step 5. Carefully feed the electrical lead wires and safety cable from the coupling on top of the
motor assembly up through the downrod. Thread the downrod into the coupling on top of the
Downrod
motor assembly until the hitch pin holes in the downrod and the hitch pin holes in the coupling
Coupling
are aligned. (Fig. 7)
Set Screw
Set Screw
Step 6. Carefully insert the hitch pin through the holes in the coupling and the downrod. (Fig. 7)
Retaining
Hitch
Clip
Pin
NOTE: Be careful not to jam the hitch pin against the wiring inside of the downrod.
Motor
Insert the retaining clip through the hole near the end of the hitch pin until it snaps into its locked
Assembly
position. (Fig. 7)
Fig. 7
Step 7. Tighten the two set screws in the coupling on top of the motor assembly firmly. (Fig. 7)