• Do not pull the appliance by the handle.
• Install the appliance in a safe and suitable
place that meets installation requirements.
• Keep the minimum distance from other
appliances and units.
• Before mounting the appliance, check if
the appliance door opens without restraint.
• The appliance is equipped with an electric
cooling system. It must be operated with
the electric power supply.
• The built-in unit must meet the stability
requirements of DIN 68930.
Cabinet minimum height
(Cabinet under the worktop
minimum height)
Cabinet width
Cabinet depth
Height of the front of the
appliance
Height of the back of the
appliance
Width of the front of the ap‐
pliance
Width of the back of the ap‐
pliance
Depth of the appliance
Built in depth of the appli‐
ance
Depth with open door
Ventilation opening mini‐
mum size. Opening placed
on the bottom rear side
Mains supply cable length.
Cable is placed in the right
corner of the back side
Mounting screws
2.2 Electrical connection
WARNING!
Risk of fire and electric shock.
• All electrical connections should be made
by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the
rating plate are compatible with the
• Always use a correctly installed
• Do not use multi-plug adapters and
• Make sure not to cause damage to the
• Do not let mains cables touch or come
578 (600) mm
• The shock protection of live and insulated
560 mm
550 (550) mm
• Connect the mains plug to the mains
594 mm
576 mm
• If the mains socket is loose, do not
• Do not pull the mains cable to disconnect
595 mm
• Use only correct isolation devices: line
559 mm
567 mm
• The electrical installation must have an
546 mm
1027 mm
560x20 mm
• This appliance is supplied with a main
1500 mm
2.3 Use
4x25 mm
• Do not change the specification of this
• Make sure that the ventilation openings
• Do not let the appliance stay unattended
• Deactivate the appliance after each use.
electrical ratings of the mains power
supply.
shockproof socket.
extension cables.
mains plug and to the mains cable. Should
the mains cable need to be replaced, this
must be carried out by our Authorised
Service Centre.
near the appliance door or the niche below
the appliance, especially when it operates
or the door is hot.
parts must be fastened in such a way that
it cannot be removed without tools.
socket only at the end of the installation.
Make sure that there is access to the
mains plug after the installation.
connect the mains plug.
the appliance. Always pull the mains plug.
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
isolation device which lets you disconnect
the appliance from the mains at all poles.
The isolation device must have a contact
opening width of minimum 3 mm.
plug and a main cable.
WARNING!
Risk of injury, burns and electric shock or
explosion.
appliance.
are not blocked.
during operation.
ENGLISH
205