TROUBLESHOOTING
Danger due to electrical voltage!
Handling the machine with connected power supply may result in serious injury or
death.
Disconnect the machine from the power supply before starting work to
eliminate defects!
Many possible sources of error can be eliminated in advance if the machine is properly connected
to the power supply.
If you are unable to carry out the necessary repairs properly and/or do not have the required
training, always consult a specialist to solve the problem.
Trouble
Motor does not run
Burn marks on the
workpiece
Finished dimension of the
workpiece does not
correspond to the cutting
width set on the rip fence
Workpiece clamps when
being pushed forward
Saw blade is not square or
fence is not square to saw
blade
HOLZMANN Maschinen GmbH
WAR N I N G
Possible cause
Switch defective
Saw blade guard not
completely closed – limit
switch
Electrical system defective
Emergency stop is activated
Blunt saw blade
Dimension scale for the
cutting width misaligned
Blunt saw blade
Riving knife does not match to
the saw blade used
Table top or fence are not
aligned parallel
www.holzmann-maschinen.at
TROUBLESHOOTING
Solution
Repair switch
Close the saw blade guard well so that the
limit switch is activated and push the reset
button to confirm.
Check main cable, plug and motor; repair or
replace, if necessary
Check fuse
Deactivate the emergency stop and push
the reset button to confirm
Change saw blade
Reset the zero point of the rip fence
Change saw blade
Riving knife thickness must be equal to or
greater than saw blade thickness
Align table parallel to saw blade