Connecting the Mains Cable
General
A mains cable that is suitable for the mains voltage must be fitted before start-
up.
Specified mains
Device type
cable
2160 UL
2225 UL
4075 UL
4090 UL
4120 UL
4185 UL
4210 UL
4300 UL
4325 UL
Device type
2160 UL
4075 UL
4090 UL
2225 UL
4120 UL
4185 UL
4210 UL
4300 UL
4325 UL
*
AWG = American Wire Gauge
Preparing the
mains cable
Danger of injury and damage to property due to short circuits.
On the stripped mains cable, fit all phase conductors and the neutral conductor
with wire end ferrules and fit the ground conductor with a cable lug.
If no wire end ferrules are used, short circuits may occur between the phase con-
ductors or between the phase conductors and the neutral conductor.
22
Cable diameter
.43 bis .83 in. (11 bis 21 mm)
.75 bis 1.06 in. (19 bis 27 mm)
Mains voltage
3 x 480 V
Cable type for USA: Extra-hard usage
Type S, SE, SO, SOO, SOOW, ST, STO, STW, STOW
CAUTION!
Cable cross section
USA *
AWG14 / 5G2.5
AWG12 / 5G2.5 / 5G4
AWG8 / 5G10