Configuration mode
Overview of the
Charging settings: Settings for the battery
setting options
-
in configuration
-
mode
-
-
-
Additional functions: Additional functions
General options: General settings
Reset Settings
Entering the
configuration
mode
1
Enter the configuration menu as follows:
1
Type of battery, e.g., "Wet".
Charging characteristic, e.g., "IU".
Capacity (Ah) or charging time (h), depending on the charging characteristic.
Cells: Voltage (V) and number of battery cells or automatic setting of the
number of cells.
CAUTION!
Risk of damage to the battery due to incorrectly set values.
This can result in damage to property.
▶
Only use the automatic setting of the number of cells for batteries with
the following nominal voltage values: 12 V and 24 V for 24 V devices, 24
V and 48 V for 48 V devices.
▶
Do not use the automatic setting of the number of cells on deeply dis-
charged batteries.
Further settings:
For individual adjustment of the charging characteristic.
Use the "Up/Down" buttons to call up the following information:
-
Device serial number as well as serial number and version of the config-
uration memory.
-
PC board for control/power electronics: Hardware version and serial
number.
-
Software: Main software, secondary software, primary software, and
curve block version.
Press the "Pause/Start" button.
First, the screen appears in the basic
settings with display of date and time,
as well as the software version.
49