Equalizing
Equalizing charge
charge
OFF
-
Delay
-
-
Weekday
-
-
Manual
-
-
-
-
If a setting for the equalizing charge is activated, a symbol next to the set
ampere hours/the set charging time in the home screen indicates whether the
equalizing charge is being carried out or can be started.
56
No equalizing charge takes place.
If the battery remains connected to the battery charger for the duration of
the set equalising charge delay, a special form of charging takes place. This
prevents acid stratification.
The parameters for current (amperes/100 ampere hours), voltage (volts/
cell), and duration of the equalizing charge can be changed.
Specification of the day of the week on which the equalizing charge is to take
place.
The parameters for current (amperes/100 ampere hours), voltage (volts/
cell), and duration of the equalizing charge can be changed.
An equalizing charge can be activated manually by pressing a button on the
display.
The equalizing charge starts after the set delay with the set parameters.
The parameters for current (amperes/100 ampere hours), voltage (volts/
cell), and duration of the equalizing charge can be changed.
This function is only available for Pb-WET curves.
If a curve is selected that requires an
external temperature sensor, a mes-
sage appears.
Confirm the message by pressing
1
the "Pause/Start" button.