BASIC BUTTON INSTRUCTIONS
Item
Button
1.
2.
3.
4.
EN
Short press: Confirm setting.
Long press: Enter the function menu setting.
Short press:
a) In the Setting Status, short press CODE, it will exit the current
operation and
return to the standby interface.
b) In the Standby Status, short press the CODE, A dot will be indicated
in the corner, now entering the code leaning mode.
Now first click the button on the hand transmitter you want to use,
the dot may disappear, then press again the same button on the hand
transmitter, the dot will flash, here, the code learning is finished.
Long press: Clear the coded remote.
Press and hold CODE button until a letter "C" is indicated on the
display.
All stored remotes will be deleted.
Short press: Open the door.
Long press: Increase the resilience.
Press and hold the UP button, after 4 seconds, it will scroll to display
0-1-2-3, choose the number you want. 1=increase the resilience
25%,2=increase the resilience 50%,3=increase the resilience 75%.
Short press: Close the door.
Long press: Restore Factory Settings.
Keep press DOWN button, after 4 seconds, it will scroll to display
, then the garage door opener will restart.
PS: Restart means all settings are back to factory settings, all learning
things need to be done again except the transmitter learning code.