E. MAINTENANCE ALARM-OPERATION CYCLES
COUNT SETTING
a) Press and hold SET Buton un�l "1" appears on
the display, next press the UP buton un�l "E"
appears on the display to enter this func�on
se�ng then release the buton.
b) Press the SET buton again. The unit is now in
the maintenance alarm adjustment mode. And
then you will see a figure "0" with flash dot
appears on the display.
c) Press UP / Down buton, you can select the
opera�on cycles you need the opener to make
you no�ce. You can choose from "1-5" set.
Figure "1" means, a�er garage door operated to
1000 �mes, the L.E.D light will flash 10 �mes
quickly a�er the door stop working every �me. In
order to make you no�ce that your garage door
need to do maintenance. And at the same �me,
you will see a figure "t" appears on the display.
Figure "2" means the maintenance alarm count
cycle is set on 2000 �mes.
Figure "3" means the maintenance alarm count
cycle is set on 3000 �mes.
Figure "4" means the maintenance alarm count
cycle is set on 4000 �mes.
Figure "5" means the maintenance alarm count
cycle is set on 5000 �mes.
d) Press SET buton to confirm the set and it will
be back to standby status automa�cally and
display "ll".
NOTE:
1. The opera�on count cycles is set on "0"as
standard in factory.
2. "t" appears on display and led light flashes 10
�mes quickly means the door lost balance,
strongly recommend the maintenance for garage
doors.
3. "Check" the status, or "Re-learn" the travel
limit after maintenance alarm cautions.