3.3. LOWER PANEL
The PowerNET P-600 has a cable lock in the lower area where the tension
feeding
and measurement cables are, this cable cannot be disconnected from the
equipment. The current sensors input connector allows to be disconnected and kept
separately. Through this connection the electrical network signals will be monitored.
TN
Current connector = Conector Corrente
Tension cable = Cabo de Tensão
3.3.1. TENSION FEEDING AND MEASUREMENT CABLE
The maximum allowed tension between phase and neutral is 300Vca
The tension measurement conductors identified by the rings A, B, C and N, are
utilized to monitor the triphasic system.
The equipment feeding conductors are identified by the rings F and N. The
maximum tension for this circuit is 300Vca, except in special series manufactures upon
request
Conductors
A, B, C
PowerNET P-600
Illustrative picture
IMPORTANT:
The maximum tension between phases is 500Vca
6 wires version (standard):
Maximum tension between circuits
500Vca
Manual de Instalación y Operación
Description
Tension measurement
105