FAULT
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Undo the screw (D) of the pressure connec-
4)
tion.
Connect the pressure gauge (E) to the pres-
5)
sure test point (F).
Turn the gas supply tap back on.
6)
Light the burner and turn the knob to the full
7)
fl ame setting, then check that the pressure
reading complies with the values in the table
(see back of manual).
Turn off the burner, disconnect the pressure
8)
gauge.
Restore the initial conditions after completing
9)
the operation.
See paragraph "TROUBLESHOOTING" dof the
User instructions manual.
HANDLING AND INSTALLATION
INSTRUCTIONS AND WARNINGS FOR HANDLING AND INSTALLATION
NOTE: Read the following sections
carefully before performing any handling and
installation operations; read the following
sections of the "User instruction manual":
– Hazards and safety provisions during trans-
port.
– Hazards and safety provisions during assem-
bly.
– Hazards and safety provisions during installa-
tion, commissioning, adjustments and part re-
placement.
3319961_inst_GB_rev.1
CHECKING GAS PRESSURE
FAULT
TROUBLESHOOTING
tion operations shall be carried out in accor-
dance with current legislation on health and
safety at work. If necessary, the person autho-
rised to carry out these operations should or-
ganise a "safety plan" to protect the people
directly involved.
(water, electricity and gas) must be set up ex-
clusively by suitably qualifi ed staff , in accor-
dance with local requirements.
C
A
C
B
WARNING: All handling and installa-
WARNING: The necessary connections
ENGLISH
F
E
D
7