ENGLISH
The manufacturer has tested the appliance
with its own mains gas, identifi ed by the stick-
er applied to the nameplate.
If the type of gas to connected is diff erent from
that used for testing, proceed as follows.
Close the gas supply tap (A).
1)
Replace the top burner nozzles (see pag.
2)
15).
Replace the top burner pilot light nozzles
3)
(see pag. 16)
Adjust the gas control valve to the minimum
4)
setting (see page 13).
Remove the testing gas sticker from the
5)
nameplate (B) and apply the new one to
identify the gas being used.
Remove the sticker from the appliance and
6)
apply the new one (C) with the category of
the country of installation.
NOTE: After completing the opera-
tion, check for any gas leaks or faults.
WARNING: Before commissioning the
appliance, the system must be tested to as-
sess the operating conditions of every single
component and detect any anomalies. In this
stage, it is important to check that all health
and safety requirements are strictly adhered
to.
To test the system, make the following checks:
Turn on the gas supply tap and check that the
1)
connections are right.;
Check that the mains gas is the same as that
2)
used for commissioning of the appliance, and
carry out the conversion procedure if neces-
sary (see page 12).
12
CONVERSION OF GAS SUPPLY
C
AL
AL
AT
AT
BE
BE
BE
BE
BG
BG
B
TESTING OF THE APPLIANCE
3)
4)
5)
6)
7)
After testing, if necessary instruct the user in all
the skills necessary for putting the appliance into
operation in conditions of safety, in accordance
with legal requirements.
HANDLING AND INSTALLATION
II2H3B/P: G20/20mbar, G30/30mbar
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
3P
II2H3B/P: G20/20mbar, G30/50mbar
II2H3P: G20/20mbar, G31/50mbar
II2E+3+: G20-G25/20-25mbar, G30-G31/28_30-37mbar
II2E+3B/P: G20-G25/20-25mbar, G30/30mbar
II2E+3P: G20-G25/20-25mbar, G31/37mbar
II2E+3B: G20-G25/20-25mbar, G30/30mbar
II2H3B/P: G20/20mbar, G30/30mbar
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
A
G20
kW
m3/h
mbar
G31
kW
G25
m3/h
mbar
kW
G30
kW
Kg/h
mbar
G20
kW
m3/h
mbar
G31
kW
Kg/h
G25
m3/h
kW
mbar
G30
kW
Kg/h
mbar
Check that the hob burner is igniting correctly
and his combustion.
Check the gas pressure and fl ow-rate at mini-
mum and maximum settings and adjust if nec-
essary (see page 7).
Check that the safety thermocouple is working
correctly.
Check that there are no gas leaks.
Check that the nameplates specify the correct
gas for the country of use.
IS
II2H3B/P: G20/20mbar, G30/30mbar
IS
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
IT
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
IT
II2H3B/P: G20/20mbar, G30/30mbar
IT
II2H3P: G20/20mbar, G31/37mbar
LT
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
LT
II2H3B/P: G20/20mbar, G30/30mbar
LT
II2H3P: G20/20mbar, G31/37mbar
LU
II2H3B/P: G20/20mbar, G30/30mbar
LU
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
01
rif.
0051
mbar
Kg/h
~
~
~
CE n.
TYPE
01
rif.
0051
mbar
~
~
~
CE n.
TYPE
3319961_inst_GB_rev.1

Publicidad

loading