PREPARATION WORK
Before starting installation, decide on the position of
the indoor and outdoor units, taking into account the
minimum space reserved around the units.
WARNING
• Do not install your air conditioner in a wet room
such as a bathroom or laundry etc.
• The installation site should be 250 cm or more
above the floor.
Installation of the Mounting
Plate
1
Always mount the rear panel horizontally and
vertically.
2
Drill 32 mm deep holes in the wall to fix the
plate.
3
Insert the plastic anchors into the hole.
4
Fix the rear panel on the wall with provided
tapping screws.
5
Be sure that the rear panel has been fixed firmly
enough to withstand the weight.
NOTE
• The shape of the mounting plate may be different
from the one above, but installation method is
similar.
Drilling a Hole in the Wall for
the Piping
1
2
• The hole must slope downwards towards the
exterior.
NOTE
• Keep the drain pipe down towards the direction of
the wall hole, otherwise leakage may occur.
Ø 5 0
Make the piping hole (Ø 55) in the wall at a slight
downward slant to the outdoor side.
Insert the piping-hole sleeve into the hole to
prevent the connection piping and wiring from
being damaged when passing through the hole.
Indoors
WARNING
EN
Outdoors
5 mm
15