3.1.1 How to install the CO pressure cartridge
Fig.6
1.
Tilt the CO cartridge sheath in the cover downwards to a maximum angle of 90° and
unscrew the housing (Fig. 6.
2.
Insert an unused 16 gramme CO pressure cartridge (Fig. 7).
3.
Screw the CO cartridge sheath back onto the dispenser cover.
4.
You should hear a clicking sound. This signals that the cartridge seal was pierced when
the sheath was screwed back onto the cover, enabling the gas to ow into the keg (Fig. 8).
5.
Tilt the CO cartridge sheath back up into the dispenser cover.
6.
Close the beer dispenser cover.
3.2 5 L Heineken keg
Fig.9
PLEASE NOTE
Heineken kegs are pre- lled with CO , so no pressure regulator or CO pressure
cartridge are required. Correspondingly, the regulator knob on the cover is also not
required.
1.
Place the CO connection hose next to the CO cartridge sheath. Neither of these
components is required for Heineken kegs (Fig. 9).
2.
You will need a screwdriver to remove the green cover from your Heineken keg (Fig. 10).
3.
Connect the beer hose supplied with the dispenser to one of the Heineken adapters
also supplied with it (Fig. 11).
4.
Attach the adapter and beer hose to the Heineken keg (Fig. 12).
5.
Place the keg in the dispenser cooling chamber.
6.
Attach the other end of the beer hose to the connector on the dispensing unit.
7.
Close the dispenser cover.
Fig.7
Fig.10
Fig.11
Fig.8
Fig.12
CASO Beer Master
DE
EN
ES
SV
FR
IT
NL
59