Interior view
8
7
6
Fig. 3: Interior view
1
Cable glands *
2
Terminals 3 and 4 for connecting an external
switching contact (downgrade input)
3
MCU (MENNEKES Control Unit)
4
Terminals for connecting the data line (for
Modbus RTU)
5
Terminals for connecting an external shunt re-
lease
6
DIP switches
7
Connection for the MENNEKES configuration
cable
8
Connection terminals for power supply
* Additional cable glands are installed on the top
and bottom.
3.5
LED status display
The LED status display indicates the operating
status (standby, charging, fault) of the product.
8
1
2
3
4
5
Standby
Response of
Meaning
the LEDs (de-
fault colour
setting)
The product is ready for use. No
vehicle is connected to the
product.
Lights up
blue.
No vehicle is connected to the
product. Authorisation has oc-
curred (valid for 5 minutes).
Flashes blue.
A vehicle is connected to the
product. Authorisation has not oc-
curred.
Flashes blue.