Descargar Imprimir esta página

Roger Technology B70/1DCHP Instrucciones Y Advertencias Para El Instalador página 70

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 144
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when closing.
Contact with 8k2 resistor. The gate reverses only when closing.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate reverses only when opening.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate always reverses
STEP MODE.
PARTIAL OPENING
OPENING
CLOSING.
STOP.
Courtesy light. The output COR is managed from the remote control. The light remains lit as long as the remote control
is active. The parameter
Courtesy light in step mode (PP). The output COR is managed from the remote control.
The remote control turns the courtesy light on and off. The parameter
(1)
enable the command. Example: parameters
seconds by pressing CHB on the remote control. Press CHB to activate partial opening.
Selecting courtesy light mode
Disabled.
ACTIVE. The light remains lit for the entire duration of the manoeuvre.
From 3 to 90 s. The light remains lit for the time period set after the manoeuvre is completed.
From 2 to 9 minutes. The light remains lit for the time period set after the manoeuvre is completed.
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock), the gate closes.
When the clock function is active, the gate opens and remains open. Any command signal received is ignored.
When the clock function is active, the gate opens and remains open. Any command signal received is accepted. When
the gate returns to the completely open position, the clock function is reactivated.
Enable safeguarded gate closure/opening
Enabling this parameter ensures that the gate is not left open due to an incorrect and/or accidental command.
This function is NOT enabled if:
• the gate receives a STOP command;
the sensitive edge intervenes, detecting an obstacle in the same direction in which the function is enabled. If instead the
sensitive edge detects an obstacle during the movement opposite to the one guaranteed, the function remains active.
• the number of closure attempts set by parameter
• the acquired position is lost (perform position recovery, see chapter 21).
70
COS2
N.B.: With ROGER TECHNOLOGY plug-in radio receiver board.
N.B.: With ROGER TECHNOLOGY plug-in radio receiver board.
is ignored.
(1)
(1)
(1)
(1)
and
set:
has been reached;
is ignored.

Publicidad

loading