Model
Rating BTU/Hr
Fuel Comsumption Gal/Hr
Fuel Tank Capacity Gallons
Pump Pressure PSI
Volt/Hz
Amps
Phase
Size (L x W x H)
Net Weight (Lbs)
Minimum clearance from Combustibles:
MH-0075-0M11
Top
3 ft.
Sides
3 ft.
Front
10 ft.
WARNING: FOR USE ON NON-COMBUSTIBLE FLOORING WITH MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS.
HARDWARE COMPONENTS
MH-0075-0M11
Handle
Ø5x1
10
PORTABLE HEATER SPECIFICATIONS
MH-0075-0M11
75,000
0.55
5.3
3.2
120VAC/ 60 Hz
1.3
Single
31x13x16
28
MH-0135-0M11
3 ft.
3 ft.
10 ft.
MH-0135-0M11, MH-0190-0M11 and MH-0215-0M11
Shaft fixed Bkt
Axle
T2.0xØ13xØ2
MH-0135-0M11
135,000
0.97
10.6
5.2
120VAC/ 60 Hz
2.1
Single
39x15x22
54
MH-0190-0M11
3 ft.
3 ft.
10 ft.
ASSEMBLY
M6
MH-0190-0M11
MH-0215-0M11
190,000
1.37
13.2
6.0
120VAC/ 60 Hz
120VAC/ 60 Hz
2.5
Single
40x17x22
61
MH-0215-0M11
3 ft.
3 ft.
10 ft.
M6x1
M8x1
Wheels
Kerosene Portable Heaters Manual
215,000
1.58
13.2
7.0
2.7
Single
40x17x22
61
Cap Nut