4. If the heater still does not start, turn the Power Switch "OFF". Wait 10 seconds. Turn the Power Switch
"ON".
NOTE: The major electrical components of this heater are protected by a safety fuse mounted to the PCB board located behind
the Right Side Panel. If your heater fails to start, check this fuse first and replace it as necessary. You should also check
your power source to ensure that proper voltage and frequency are being supplied to the heater.
SHUTTING DOWN THE HEATER
1. Push the Power Button to the "OFF" position.
2. Wait for heater to cool, then unplug the heater from
its power source.
RESTARTING THE HEATER
1. Wait 10 seconds after powering down the heater.
2. Push the Power Switch to the "ON" position.
3. If the heater does not start, the thermostat setting
may be lower than the ambient temperature. Turn
the Thermostat Control Knob to a higher temperature setting. If the heater still does not start, turn the Power
Switch "OFF". Wait 10 seconds. Turn the Power Switch "ON"
RESTARTING THE HEATER AFTER SAFETY SHUTDOWN
1. Push the Power Button to the "OFF" position.
2. Unplug the heater from its power source.
3. Wait 10 seconds for the system to reset.
4. Plug the heater into its power source.
5. Push the Power Button to the "ON" position.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
Kerosene Portable Heaters Manual
OPERATION
Thermostat
Control Knob
Lamp
Room Temp.Display
Power
Reset
Switch
13