7. Insert Fuel Filter in the Fuel Tank and using adjustable wrench turn the Filter 90 degrees clockwise.
8. Attach Fuel Line to Fuel Filter neck.
9. Reinstall side cover with screws provided.
ADJUSTING PUMP PRESSURE
After hours of use it may be necessary to adjust the Pump Pressure. If the heater is not producing a
strong flame: Increase the pressure by turning the adjustment screw clockwise. If the heater is producing
a flame that extends beyond the end of the heater: Reduce the pressure by turning the adjustment screw
counterclockwise.
Adjusting Pump Pressure
Model #
MH-0075-0M11
MH-0135-0M11
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
Kerosene Portable Heaters Manual
MAINTENANCE
Pump Pressure
3.2 PSI
5.2 PSI
Model #
MH-0190-0M11
MH-0215-0M11
250V/10A
Pump Pressure
6.0 PSI
7.0 PSI